500kVA Diesel Generator | Prime Power | For Export Projects
Manufacturer: WALT Power (China-based industrial diesel generator manufacturer, supplier, and exporter)
Engine Platform: DCEC Cummins heavy-duty diesel engines (QSZ13-G10 for 50Hz / QSZ13-G11 & optional QSZ13 for 60Hz)
Rated Output (50Hz / 1500 RPM): 500 kVA / 400 kW Class Prime Power (Standby: 550 kVA / 440 kW)
Rated Output (60Hz / 1800 RPM): 550 kVA / 440 kW Class Prime Power (Standby: 600 kVA / 480 kW) (Optional 475 kVA Prime / 500 kVA Standby configuration available upon request)
Alternator: 100% Copper Brushless Alternator (Stamford / Leroy Somer / WALT Power ) with AVR voltage regulation
Enclosure Options: Industrial soundproof canopy for outdoor installation with optimal acoustic attenuation
Fuel Autonomy (100% Load): 1000L base fuel tank integrated (~8–9.6 h runtime depending on frequency & duty rating)
Control System: Deep Sea (UK) or SmartGen AMF Auto-Start Controller with optional ATS & remote monitoring
Application & MOQ: Designed for OEM, EPC contracts, industrial continuous power, and bulk export. MOQ: 1 Unit.
Warranty & Standards: 12 months or 1,000 running hours; ISO9001, ISO14001, CE compliant
The WALT Power 500kVA diesel generator is engineered for industrial prime and standby power applications in export and project-based environments.
As a 500kVA-class generator set, this model is powered by heavy-duty DCEC Cummins QSZ13 industrial engines as the standard configuration. For 50Hz (1500 RPM) operations, it delivers 400 kW / 500 kVA prime power (powered by QSZ13-G10). For 60Hz (1800 RPM) operations, it delivers 440 kW / 550 kVA prime power (powered by QSZ13-G11), with an alternative 60Hz model available upon technical evaluation to meet specific 475 kVA/500 kVA project requirements.
The generator is available in flexible 50Hz and 60Hz configurations, featuring an integrated 1000L base fuel tank, soundproof canopy, and advanced Deep Sea controller. Each unit is designed for professional buyers, EPC contractors, and OEM partners who require consistent performance, clear technical specifications, and long-term serviceability.
Specifications
50Hz
60Hz
50Hz
Genset Model
WGP-C500/S
Prime Output (PRP)
400 kW / 500 kVA
Standby Output (ESP)
440 kW / 550 kVA
Engine
DCEC Cummins QSZ13-G10
Alternator
Stamford / Leroy Somer / WALT Power (100% Copper, Brushless)
Voltage
380/400/415V
Frequency – Speed
50Hz – 1500 rpm
Phase
3-Phase
Type
Silent with a soundproof canopy
Controller
Deep Sea (UK) / SmartGen AMF
Starting Method
Auto Start (12V/24V DC)
Fuel Tank capacity
1000 Liters (Integrated Base Tank)
Fuel Consumption @100% Load (PRP)
107 L/H
Fuel Consumption @75% Load (PRP)
80 L/H
Continuous Running Time
~9.3 Hours @ 100% Load / ~12.5 Hours @ 75% Load
Dimensions (L × W × H)
4750×1800×2250 mm
Genset Weight
5200 kg
Base fuel tank is designed for compact installation (integrated 1000L capacity). Extended or customized bulk fuel tank systems are available for longer continuous operation
Voltage options shown are typical configurations. Other international voltages may be customized based on destination market requirements.
Specifications are provided for reference only and may be subject to change without prior notice as part of ongoing product improvements.
Dimensions and weight may vary depending on the final engine configuration, alternator brand, and optional components.
For exact pricing, project configuration options, technical data sheets, and lead time, please contact:
Technical FAQ
Q1: Is this 500kVA diesel generator suitable for continuous prime power operation?
A: Yes. When configured for prime power (PRP) operation, this 500kVA diesel generator is designed for continuous duty within its rated load capacity, provided that standard installation, fuel quality, and maintenance procedures are maintained. The DCEC Cummins QSZ13 engine ensures excellent load acceptance and thermal stability.
Q2: What is the difference between 50Hz and 60Hz configurations for this 500kVA series?
A: For 50Hz markets (1500 RPM), the generator set is powered by the DCEC Cummins QSZ13-G10 delivering 500 kVA / 400 kW prime power. For 60Hz markets (1800 RPM), we offer the QSZ13-G11 (550 kVA / 440 kW prime power) as standard, as well as an optional 60Hz configuration rated at 475 kVA prime / 500 kVA standby to match exact project load specifications.
Q3: Which engine brands and custom configurations are available for this 500kVA class?
A: DCEC Cummins (QSZ13 series) is supplied as the standard heavy-duty configuration. For specific regional requirements or project standards, Perkins-powered, Baudouin-powered, Weichai-powered, etc. units or customized extended base fuel tanks (1500L+) can also be supplied upon technical evaluation.
Brand Statement
WALT Power is an independent diesel generator manufacturer and exporter based in China, specializing in heavy-duty industrial generator sets for global project markets.
With over a decade of experience supplying power equipment to EPC contractors, industrial operators, telecom groups, and project buyers, WALT Power focuses on engineering-grade reliability, transparent specs, and long-term serviceability rather than retail sales.
All 500kVA generator sets are manufactured and tested according to confirmed project technical parameters, application requirements, and destination grid standards.
60Hz
Genset Model
WGP-C550/S6 (Standard 60Hz)
Prime Output (PRP)
440 kW / 550 kVA (Optional 380 kW / 475 kVA configuration available upon request)
Standby Output (ESP)
480 kW / 600 kVA (Optional 400 kW / 500 kVA configuration available upon request)
Engine
DCEC Cummins QSZ13-G3
Alternator
Stamford / Leroy Somer / WALT Power (100% Copper, Brushless)
Voltage
220/230/240/440/460/480V
Frequency – Speed
60Hz – 1800 rpm
Phase
3-Phase
Type
Silent with a soundproof canopy
Controller
Deep Sea (UK) / SmartGen AMF
Starting Method
Auto Start (12V/24V DC)
Fuel Tank capacity
1000 Liters (Integrated Base Tank)
Fuel Consumption @100% Load (PRP)
121 L/H
Fuel Consumption @75% Load (PRP)
91 L/H
Continuous Running Time
~8.2 Hours @ 100% Load / ~11.0 Hours @ 75% Load
Dimensions (L × W × H)
4750×1800×2250 mm
Genset Weight
5200 kg
Base fuel tank is designed for compact installation (integrated 1000L capacity). Extended or customized bulk fuel tank systems are available for longer continuous operation
Voltage options shown are typical configurations. Other international voltages may be customized based on destination market requirements.
Specifications are provided for reference only and may be subject to change without prior notice as part of ongoing product improvements.
Dimensions and weight may vary depending on the final engine configuration, alternator brand, and optional components.
For exact pricing, project configuration options, technical data sheets, and lead time, please contact:
Technical FAQ
Q1: Is this 500kVA diesel generator suitable for continuous prime power operation?
A: Yes. When configured for prime power (PRP) operation, this 500kVA diesel generator is designed for continuous duty within its rated load capacity, provided that standard installation, fuel quality, and maintenance procedures are maintained. The DCEC Cummins QSZ13 engine ensures excellent load acceptance and thermal stability.
Q2: What is the difference between 50Hz and 60Hz configurations for this 500kVA series?
A: For 50Hz markets (1500 RPM), the generator set is powered by the DCEC Cummins QSZ13-G10 delivering 500 kVA / 400 kW prime power. For 60Hz markets (1800 RPM), we offer the QSZ13-G11 (550 kVA / 440 kW prime power) as standard, as well as an optional 60Hz configuration rated at 475 kVA prime / 500 kVA standby to match exact project load specifications.
Q3: Which engine brands and custom configurations are available for this 500kVA class?
A: DCEC Cummins (QSZ13 series) is supplied as the standard heavy-duty configuration. For specific regional requirements or project standards, Perkins-powered, Baudouin-powered, Weichai-powered, etc. units or customized extended base fuel tanks (1500L+) can also be supplied upon technical evaluation.
Brand Statement
WALT Power is an independent diesel generator manufacturer and exporter based in China, specializing in heavy-duty industrial generator sets for global project markets.
With over a decade of experience supplying power equipment to EPC contractors, industrial operators, telecom groups, and project buyers, WALT Power focuses on engineering-grade reliability, transparent specs, and long-term serviceability rather than retail sales.
All 500kVA generator sets are manufactured and tested according to confirmed project technical parameters, application requirements, and destination grid standards.
Explore 10 established diesel engine brands used in Chinese generator sets, including Cummins, Perkins, Weichai, Yuchai and more. Learn how to compare engine manufacturers, generator configurations and sourcing options for international buyers.
A practical guide to importing diesel generators from China, covering supplier selection, generator specifications, international shipping, import regulations, and customs clearance.