The WALT WDG series open-type diesel generators are designed for export-oriented industrial and commercial standby power applications.
This 16kW / 20kVA 3-phase model is commonly supplied to overseas distributors, importers, and project contractors for use in factories, construction sites, infrastructure projects, and rental fleets where reliable three-phase backup power is required.
Configured with an air-cooled diesel engine running at 3000 rpm (50Hz) or 3600 rpm (60Hz), this generator is suitable for continuous operation within its rated output, depending on the operating frequency. Electrical specifications, including voltage and frequency, can be customized to match destination market standards.
Specifications
50Hz
60Hz
50Hz
Genset Model
WDG-25000DCE/3
Max. Output
16 kW/20 kVA
Rated Output
15 kW/18.75 kVA
Rated Voltage
380/400/415V
Frequency – speed
50 Hz – 3000 rpm
DC Output
12V 8.3A
Phase
3-phase (1-phase is optional)
Starting System
Electrical with battery
Noise Level @ 7 meters
80 to 85 dBA
Fuel Tank Capacity
25 Liters
Oil Capacity
4
Continuous Running Time
5.8 hours
Genset Weight
280 Kg
Genset Size (L × W × H)
935×655×980 mm
Qty for 20′ ft/40’ft Container
40/82 sets
* Specifications are subject to change as part of continuous product improvement.
* This specification is provided for reference purposes only. Final configuration will be confirmed based on order requirements and destination market standards.
* For pricing, configuration options, and lead time, please contact:
Technical FAQ
Q1: Is this 20kVA diesel generator suitable for continuous operation?
Yes, this generator can be used for continuous operation within its rated output, depending on the operating frequency.
For the 50Hz configuration, the rated output is 15kW / 18.75kVA, with a maximum output of 16kW / 20kVA intended for short-duration use only.
For the 60Hz configuration, the rated output is 16kW / 20kVA, with a maximum output of 17kW / 21kVA for limited-time operation.
Continuous operation should always be limited to the rated output, with proper load management, ventilation, and routine maintenance to ensure stable performance and service life.
Q2: Is this generator designed for standby power or prime power applications?
This 16kW / 20kVA diesel generator is primarily designed for standby power and light prime power applications.
It is commonly used as a backup power source for industrial facilities, construction sites, and infrastructure projects, or for temporary and intermittent operation, such as rental and mobile power support.
For heavy-duty prime power or 24/7 continuous operation at high load levels, water-cooled diesel generator models with higher prime-rated capacity are recommended.
60Hz
Genset Model
WDG-25000DCE/3
Max. Output
17 kW/21 kVA
Rated Output
16 kW/20 kVA
Rated Voltage
220/230/240/440/460/480V
Frequency – speed
60 Hz – 3600 rpm
DC Output
12V 8.3A
Phase
3-phase (1-phase is optional)
Starting System
Electrical with battery
Noise Level @ 7 meters
80 to 85 dBA
Fuel Tank Capacity
25 Liters
Oil Capacity
4
Continuous Running Time
5.8 hours
Genset Weight
280 Kg
Packing Size (L × W × H)
935×655×980 mm
Qty for 20′ ft/40’ft Container
40/82 sets
* Specifications are subject to change as part of continuous product improvement.
* This specification is provided for reference purposes only. Final configuration will be confirmed based on order requirements and destination market standards.
* For pricing, configuration options, and lead time, please contact:
Technical FAQ
Q1: Is this 20kVA diesel generator suitable for continuous operation?
Yes, this generator can be used for continuous operation within its rated output, depending on the operating frequency.
For the 50Hz configuration, the rated output is 15kW / 18.75kVA, with a maximum output of 16kW / 20kVA intended for short-duration use only.
For the 60Hz configuration, the rated output is 16kW / 20kVA, with a maximum output of 17kW / 21kVA for limited-time operation.
Continuous operation should always be limited to the rated output, with proper load management, ventilation, and routine maintenance to ensure stable performance and service life.
Q2: Is this generator designed for standby power or prime power applications?
This 16kW / 20kVA diesel generator is primarily designed for standby power and light prime power applications.
It is commonly used as a backup power source for industrial facilities, construction sites, and infrastructure projects, or for temporary and intermittent operation, such as rental and mobile power support.
For heavy-duty prime power or 24/7 continuous operation at high load levels, water-cooled diesel generator models with higher prime-rated capacity are recommended.
Explore 10 established diesel engine brands used in Chinese generator sets, including Cummins, Perkins, Weichai, Yuchai and more. Learn how to compare engine manufacturers, generator configurations and sourcing options for international buyers.